The Kaps SDM examination microscope is designed for ENT specialists who are unwilling to compromise on optical quality and are looking for a high-quality, easy-maintenance microscope for carrying out examinations.
Kaps SDM is the perfect entry model and boasts a sensational price-performance ratio.
We have focused on the main features impacting medical examinations, and have combined tried-and-true Kaps optics with bright LED illumination and high operating comfort.
Kaps optics provides crystal-clear images and high-resolution details in natural colors (apochromatic optics).
The LEDone illumination system offers a number of extremely positive product characteristics that score over conventional halogen light sources:
Illumination | LEDone illumination unit |
Objective | Changeable lenses from 200 mm to 400 mm in steps of 50 mm Lenses f = 200 mm and f = 250 mm with integrated focusing (14 mm) |
Binocular tubes | Straight tube f = 125 mm or f = 159 mm |
Eyepieces | Eyepieces WF 12.5 x V or WF 10 x V (with diopter adjustment) |
Magnification | 3-step magnification changer, 5-step magnification changer at additional cost |
Fine focussing | Manual fine focusing 40 mm (optional) |
Video camera | Adaptation for C-mount video cameras by beam splitter and TV tube |
Integrated endoscope adapter | For directly adapting existing endoscope cameras |
Illumination | Coaxial cold light illumination (15 V / 150 W) with spare bulb LED illumination optional |
Objective | Changeable lenses from 200 mm to 400 mm in steps of 50 mm Lens f = 200 mm and f = 250 mm with integrated focussing (14 mm) |
Binocular tubes | Straight tube f = 125 mm or f = 159 mm, on request swivel tube f = 182 mm 0 – 210° |
Eyepieces | Eyepieces WF 12.5 x V or WF 10 x V (with diopter adjustment) |
Magnification | 3-step magnification changer, 5-step magnification changer or manual zoom 1 – 6 |
Fine focussing | Binocular or monocular |
Video camera | Adaptation of C-mount video cameras via beam splitter and TV tube |
Integrated video camera (Vision) | For direct adaptation for existing endoscopic cameras |
Iris diaphragm, green filter, spot illumination | Optional |
Illumination | Coaxial cold light illumination (15 V / 150 W) with spare bulb LED illumination optional |
Objective | Changeable lenses from 200 mm to 400 mm in steps of 50 mm Lens f = 200 mm and f = 250 mm with integrated focussing (14 mm) |
Binocular tubes | Straight tube f = 125 mm or f = 159 mm, on request swivel tube f = 182 mm 0 – 210° |
Eyepieces | Eyepieces WF 12.5 x V or WF 10 x V (with diopter adjustment) |
Magnification | 3-step magnification changer, 5-step magnification changer or manual zoom 1 – 6 |
Fine focussing | Manual fine focussing 40 mm (optional) |
Secondary viewer | Binocular or monocular |
Video camera | Adaptation of C-mount video cameras via beam splitter and TV tube |
Integrated video camera (Vision) | For direct adaptation for existing endoscopic cameras |
Iris diaphragm, green filter, spot illumination | Optional |
Illumination | Coaxial cold light illumination (15 V / 150 W) with spare bulb LED illumination optional |
Objective | Changeable lenses from 200 mm to 400 mm in steps of 50 mm Lens f = 200 mm and f = 250 mm with integrated focussing (14 mm) |
Binocular tubes | Straight tube f = 125 mm or f = 159 mm, on request swivel tube f = 182 mm 0 – 210° |
Eyepieces | Eyepieces WF 12.5 x V or WF 10 x V (with diopter adjustment) |
Magnification | 3-step magnification changer, 5-step magnification changer or manual zoom 1 – 6 |
Fine focussing | Manual fine focussing 40 mm (optional) |
Secondary viewer | Binocular or monocular |
Video camera | Adaptation of C-mount video cameras via beam splitter and TV tube |
Integrated video camera (Vision) | For direct adaptation for existing endoscopic cameras |
Iris diaphragm, green filter, spot illumination | Optional |
Binocular tubes | Straight tube f = 125 mm Binocular Swivel Tube 0-210°, f = 182 (optional) |
Objective | F = 250 mm |
Eyepieces | WF 12.5 x V with diopter adjustment WF 10 x V with diopter adjustment (optional) Other on request |
Magnification | -step apochromatic magnification changer |
Filter | Swing-in green filter |
Illumination | Coaxial cold light illumination (15 V / 150 W) with spare bulb LED illumination (optional) |
Handles | Ergonomic handle, bilateral, 360°, adjustable with disengage knob |
Binocular tubes | Straight tube f = 125 mm Binocular Swivel Tube 0-210°, f = 182 (optional) |
Objective | F = 250 mm |
Eyepieces | WF 12.5 x V with diopter adjustment WF 10 x V with diopter adjustment (optional) Other on request |
Magnification | 1:6 Zoom |
Filter | Swing-in green filter |
Illumination | Coaxial cold light illumination (15 V / 150 W) with spare bulb LED illumination (optional) |
Handles | Ergonomic handle, bilateral, 360°, adjustable with disengage knob |
G35 ENT Unit is constitute of two parts: operation table and mini writing table, G35 ENT Unit is able to attach various of medical equipment, like ENT patient chair, endoscope, CCD camera, cold light source, medical monitor, etc. By it’s simple design and small size, perfectly using the clinic space. The major material is made of ABS, table top is made of top white marble glass, anti-infection and easy for cleaning.
G65 ENT Unit is constitute of operation table and writing table. The main frame is made of durable steel, non rusting, long lasting. The metal frame was surrounded by the ABS appearance. The table top is made of top white marble glass, it’s anti-infection and easy for cleaning.
G65 ENT Unit have two air storage tank. Compressor and vacuum pump will start working automatically after power on and stop working automatically when storage tank are full of air.
Negative system has 10 seconds delay function after putting suction gun back to original position. Warning system will alarm when the dirt reach to limit warning. Vacuum gauge, bacterial filters, 1.5 liters liquid container and effective device to prevent overflow.
Compressed air system continuously adjustable from 0.1 to 4 bars for spray, spray liquid with autoclavable nozzle for cleaning. Inbuilt motor suction unit with capacity of 70 liters per minute. Compressor and vacuum pump will automatically shut down after working continuously for more than 20 minutes. Stainless steel tank for compressed air of capacity of 1.5, Compressor unit completely separate from suction unit. Handle for compressed air have a regulation valve.
Laryngoscope pre-heater device, heating system to heat the instruments. 38℃ constantly warm water rinsing system.
Derived from a long line of designs, the FUTURENT® ENT treatment unit is ergonomically designed to simplify ENT OPD procedures, vastly improve efficiency and reduce user fatigue in the ENT consulting / treatment room. Touch-screen operation, hygienic materials, carefully selected finishes and other elements are combined to form the basis of an efficient, durable and patient-friendly setting. Modern electronics help optimize efficiency and minimize downtime. Modular furniture can be added to the FUTURENT® in accordance with particular requirements, available space and budget to create an ergonomic ENT suite. This further improves efficiency and gives the consulting / treatment room a professional ambience.
The Futurent® can be equipped with a wide selection of integrated functions to accommodate specific requirements and budget.
A conveniently positioned USB port allows the quick transfer of images and videos to USB data storage devices.
Micronomic 50 metal mobile treatment unit, standard equipped with a suction system and cold light system. Due to its compact dimensions, this treatment unit is ideal for use at the ENT clinic, in the outpatient clinic and for emergency care.
The fully automatic Entermed patient chair is a comfortable doctor and patient-friendly chair. The 300 degree rotatable seat is smooth to operate and offers a lot of freedom of movement. The chair is automatically adjustable in height (from 54 to 74 cm) and can be loaded up to more than 150 kg.
In addition to the well-designed foot pedal, the Entermed patient chair can be operated using the control panels on the side. The side controls have buttons on one side where pre-programmed positions can be selected. This is easy to program yourself.
The backrest and leg rest are perfectly synchronized, making the positions comfortable for the patient. The positions range from completely horizontal to a neat upright position.
We offer exclusive design, excellent quality and cost effective endoscopes. Outstanding image quality. Exceptional luminosity and brightness. Storz / Wolf and ACMI connections.
FEATURE | SINUSCOPES | SINUSCOPES | OTOSCOPES | LARYNGOSCOPES | FLEXIBLE SCOPE |
---|---|---|---|---|---|
Diameter | 3.0mm | 4.0mm | 3.0mm | 6.0mm | 8.0mm | X |
Working Length | Approx. 140mm | Approx. 175mm | 100mm |140mm | Approx. 175mm | X |
Direction of View | 0° 30° 70° | 0° 30° 45° 70° | 0° 30° | 70° | X |
Field of View | X | X | X | X | 85° |
Depth of Field | X | X | X | X | 2,5 – 50mm |
Outer Ø insertion/td> | X | X | X | X | 3,4mm |
Outer Ø distal end | X | X | X | X | 3,4mm |
Range of distal tip | X | X | X | X | up 130° down 130° |
Record and document important images & videos from your endoscopic exams, procedures and surgeries.
Endodigi is a family of digital video/image recorders including software and hardware systems, designed to work with real time video High Definition (HD) or Standard Definition (SD).
View live video from your camera while recording images and audio.
Endodigi is simple enough to work seamlessly in your clinic and powerful enough to provide all the documentation needs of any practice capturing media files.
SPECIFICATION | |
---|---|
Model | AC 40 |
Manufacturer | Interacoustics |
Country of Origin | Denmark |
Included Parts |
|
Optional Part |
|
Available Tests | Basic License | Extended License |
---|---|---|
Basic Audiometry | X | X |
Bekesy | X | X |
SISI | X | X |
Langenbeck | X | X |
Stenger | X | X |
Modified Hughson Westlake | X | X |
ABLB | X | X |
Speech Testing with Mic/CD | X | X |
Weber | X | X |
Build in Wave Files | X | X |
Binaural Speech | X | X |
Hearing Loss Stimulator (HLS) | X | X |
Tone Decay | X | X |
Pediatric Noise | X | |
MLD | X | |
Multi Frequency | X | |
Free Field Power (4×20W) | X | X |
MHA | X | X |
QuickSIN | Optional | Optional |
TEN Test | Optional | X |
High Frequency (HF) | X | X |
Free field Lineout | X | X |
Hybrid Mode – PC Control Mode | Optional | Optional |
Sync Mode – Audiogram Transfer | Optional | Optional |
TECHNICAL SPECIFICATION | ||||||||
---|---|---|---|---|---|---|---|---|
Power Supply | 240V / 0.4A 50 Hz | |||||||
Weight | 7.9kg / 17.4lb | |||||||
Dimensions (L×W×H) | 522×366×98 cm / 20.6×14.4×3.9 inch | |||||||
Display | 8.4 inch high resolution color display 800×600 pixel | |||||||
Compatible Software | Diagnostic Suit – Noah OtoAccess XML Compatible | |||||||
Warm Up Time | Approximately 1 minute | |||||||
Patient Response Switch | Two push Button | |||||||
Operation Environment | Temperature: 15 – 35 °∁ Relative Humidity: 30 – 90 % Ambient Pressure: 98 – 108 kPa |
|||||||
Monitor | Real stereo output through build in speaker or through external earphone or assist monitor | |||||||
Stimuli | Tone | 125-20000Hz separated in two ranges 125-8000Hz and 8000-20000Hz. | ||||||
Warble Tone | 1-10 Hz sine +/- 5% modulation | |||||||
Pediatric Noise | A special narrowband noise stimulus. The bandwidth is frequency depended 125-250 Hz 29%, 500Hz 24%, 750 Hz 20%, 1kHz 17%, 1.5kHz 13%, 2kHz 11%, 3kHz 9% from 4kHz and up is fix 8%, | |||||||
Wave file | 44100Hz sampling, 16 bits, 2 channels | |||||||
Masking | Automatic selection of narrow band noise (or white noise) for tone presentation and speech noise for speech presentation. IEC 60645-1 2012, 5/12 Octave filter with the same center frequency resolution as pure Tone. White noise: 80-20000Hz measured with constant bandwidth Speech Noise. IEC 60645-2:1993 125-6000Hz falling 12dB/octave above 1KHz +/-5dB | |||||||
Presentation | Manual or Reverse. Single or multiple pulses. | |||||||
Frequency Range | 125Hz to 8kHz (Optional High Frequency: 8 kHz to 20 kHz) 125Hz, 250Hz, 750Hz, 1500Hz and 8kHz may freely be deselected | |||||||
External Signal | Speech replaying equipment connected to the CD inputs must have a signal-to-noise ratio of 45 dB or higher. The speech material used must include a calibration signal suitable for adjusting the input to 0 dBVU. | |||||||
Free Field output (non-powered) | Power Amplifier and Loud Speaker (With an input of 7 Vrms – Amplifier and loudspeakers must be able to create a Sound Pressure Level of 100 dB in a distance of 1 meter) | |||||||
Intensity | Available Intensity Steps is 1, 2 or 5dB Extended range function: If not activated, the Air Conduction output will be limited to 20 dB below maximum output | |||||||
Speech | Frequency Response | |||||||
Frequency (Hz) | Linear [dB]. | FFequv [dB] | ||||||
Ext. sign | Int. sign | Ext. sign | Int. sign | |||||
TDH 39 | 125-250 | +0/-2 | +0/-2 | +0/-8 | +0/-8 | |||
250-4000 | +2/-2 | +2/-1 | +2/-2 | +2/-2 | ||||
4000-6300 | +1/-0 | +1/-0 | +1/-0 | +1/-0 | ||||
DD45 | 125-250 | +0/-2 | +1/-0 | +0/-8 | +0/-7 | |||
250-4000 | +1/-1 | +1/-1 | +2/-2 | +2/-3 | ||||
4000-6300 | +0/-2 | +0/-2 | +1/-1 | +1/-1 | ||||
E.A.R Tone 3A | 250-4000 | +2/-3 | +4/-1 | Non-linear | ||||
IP30 | 250-4000 | +2/-3 | +4/-1 | Non-linear | ||||
250-4000 | +12/-12 | +12/-12 | Non-linear | |||||
Internal Storage | 1000 clients and 50.000 sessions/measurements/audiograms (may depend on session type/size) | |||||||
External Devices (USB) | Standard PC mouse and Keyboard (for data entry) Supported printers (Please contact distributor for a list of approved printers) | |||||||
Patient Communication | Talk forward and talk back | |||||||
HDMI output | Provides a copy of the built-in screen in HDMI format 800×600 resolution | |||||||
Data Connections (sockets) | 4 x USB A 1 x USB B for PC connection (compatible with USB 1.1 and later) 1 x LAN Ethernet (not used) | |||||||
Input Specifications | TB | 212 uVrms at max. gain for 0dB reading Input impedance : 3.2KOhm | ||||||
Mic.2 | 212 uVrms at max. gain for 0dB reading Input impedance : 3.2KOhm | |||||||
CD1/2 | 16mVrms at max. gain for 0dB reading Input impedance : 47KOhm | |||||||
TF (side panel) | 212uVrms at max. gain for 0dB reading Input impedance : 3.2KOhm | |||||||
TF (front panel) | 212uVrms at max. gain for 0dB reading Input impedance : 3.2KOhm | |||||||
Wave files | Plays wave file from internal SD card | |||||||
Output Specifications | FF 1/2/3/4 Line output | 7Vrms at 2KOhms load 60-20000Hz -3dB | ||||||
FF 1 / 2 / 3 / 4 – powered | 4x20W (only 2x20W can be used by software at the moment) | |||||||
Left & Right | 7Vrms at 10 Ohms load 60-20000Hz -3dB | |||||||
Ins. Left & Right | 7Vrms at 10 Ohms load 60-20000Hz -3dB | |||||||
HF Left & Right | 7Vrms at 10 Ohms load 60-20000Hz -3dB | |||||||
HLS | 7Vrms at 10 Ohms load 60-20000Hz -3dB | |||||||
Bone 1+2 | 7Vrms at 10 Ohms load 60-20000Hz -3dB | |||||||
Ins. Mask | 7Vrms at 10 Ohms load 60-20000Hz -3dB | |||||||
Monitor headset (side panel) | 2x 3Vrms at 32 Ohms / 1.5Vrms at 8 Ohms load 60-20000Hz -3dB | |||||||
Assist Mon. | Max.3.5Vrms. by 8 Ω load 70Hz-20kHz ±3dB |
SPECIFICATION | |
---|---|
Model | AD528 |
Manufacturer | Interacoustics |
Country of Origin | Denmark |
Included Parts |
|
Optional Part |
|
Available Tests | Basic License | Extended License |
---|---|---|
Air, Bone and Free-field | X | X |
Speech: CD,MP3, Microphone or Wave | X | X |
Stenger | X | X |
Modified Hughson Westlake | X | X |
ABLB | X | |
SISI | X | |
Békésy | X | |
Langenbeck | X | |
Weber | X | |
Speech in noise and binaural speech) | X | |
Sync license for integration with NOAH, local EMR systems or OtoAccess | X |
TECHNICAL SPECIFICATION | ||||||||
---|---|---|---|---|---|---|---|---|
Power Supply | 240V / 0.4A 50 Hz | |||||||
Weight | 1.5kg / 3.3lb | |||||||
Dimensions (L×W×H) | 11×28×36 cm / 4.3×11×14 inch | |||||||
Display | 5.0 inch high resolution color display 480×272 pixel | |||||||
Compatible Software | Diagnostic Suit – Noah OtoAccess XML Compatible | |||||||
Internal Battery | 230mAh, Li | |||||||
PC Control (USB) | Input/output for communication | |||||||
Operation Environment | Temperature: 15 – 35 °∁ Relative Humidity: 30 – 90 % Ambient Pressure: 98 – 108 kPa |
|||||||
Printer (Optional) | HM-E300 Printer Language: HP PLC3 / HP PLC3 GUI | |||||||
Patient Response | One handheld push button | |||||||
Patient communication | Talk forward(TF) and Talk back (TB) | |||||||
Monitor | Output through build in speaker, monitor headset or speaker | |||||||
Stimuli | Tone | 125-8000Hz | ||||||
Warble Tone | 1-10 Hz sine +/- 5% modulation | |||||||
Wave file | 44100Hz sampling, 16 bits, 2 channels | |||||||
Masking | Automatic selection of narrow band noise (or white noise) for tone presentation and speech noise for speech presentation. Narrow band noise: IEC 60645-1 2017, 5/12 Octave filter with the same center frequency resolution as pure Tone. White noise: 80-20000Hz measured with constant bandwidth Speech Noise: IEC 60645-2:1993 125-6000Hz falling 12dB/octave above 1KHz +/-5dB | |||||||
Presentation | Manual or Reverse. Single or multiple pulses. | |||||||
Frequency Range | 125Hz to 8kHz | |||||||
Free Field output (non-powered) | Power Amplifier and Loud Speaker (With an input of 7 Vrms – Amplifier and loudspeakers must be able to create a Sound Pressure Level of 100 dB in a distance of 1 meter) | |||||||
Intensity | Available Intensity Steps is 1, 2 or 5dB | |||||||
Speech | Frequency Response | |||||||
Frequency (Hz) | Linear [dB]. | FFequv [dB] | ||||||
Ext. sign | Int. sign | Ext. sign | Int. sign | |||||
DD45 | 125-250 | +0/-2 | +1/-0 | +0/-8 | +0/-7 | |||
250-4000 | +1/-1 | +1/-1 | +2/-2 | +2/-3 | ||||
4000-6300 | +0/-2 | +0/-2 | +1/-1 | +1/-1 | ||||
IP30 | 250-4000 | +2/-3 | +4/-1 | Non-linear | ||||
250-4000 | +12/-12 | +12/-12 | Non-linear | |||||
Internal Storage | 50,000 sessions (500 clients, 100 sessions/client) | |||||||
External Devices (USB) | Standard PC mouse and Keyboard (for data entry) Supported printers (Please contact distributor for a list of approved printers) | |||||||
External Signal | Speech replaying equipment connected to the aux input must have a signal to noise ratio of 45dB or higher. The speech material used must include a calibration signal suitable for adjusting the input to 0dB VU | |||||||
Microphone (Live speech) | The microphone of the MTH400m is used for live speech. Microphone gain must be adjusted to 0VU prior to use. |
SPECIFICATION | |
---|---|
Model | AD226 |
Manufacturer | Interacoustics |
Country of Origin | Denmark |
Included Parts |
|
Optional Part |
|
Available Tests |
|
Extended License |
|
TECHNICAL SPECIFICATION | ||
---|---|---|
Patient Response switch | One push button | |
Patient communication | Talk Forward (TF) | |
Input | Tone, Warble Tone +5%, 5Hz (true sine wave frequency modulation). | |
Output | Left, Right, Bone L+R, Insert Phones, Insert Masking | |
Dimensions (L×W×H) | 30x23x9cm / 12x9x4 inches. | |
Weight | 1.3kg / 2.9lb | |
Power Supply | 5VDC max 1.6A UE10 type only | |
Batteries | 4×1.5V/1.2V Alkaline/NiMH Type AA Note: When the instrument is battery operated the maximum stimuli output level is reduced 20dB | |
Operation environment Temperature | Temperature: 15-35°C Relative Humidity: 30-90% Non-condensing Ambient pressure: 98-104 kPa | |
Warm Up Time | Approximately 1 Minute | |
Internal storage | 500 Patient | |
Data Connections (sockets) for connection of accessories | 1 x USB A for keyboard or printer 1 x USB B for PC connection (compatible with USB 1.1 and later) | |
External devices (USB) | Standard PC keyboard (for data entry) Supported printers: Please contact distributer for a list of approved PC printers | |
Display | 4,3” (480×272) TFT color display | |
Compatible software | Diagnostic Suite – Noah OtoAccess and XML compatible | |
Stimuli | Tone | 125-8000Hz |
Warble Tone | 5Hz sine +/-% modulation | |
Masking (Narrow band noise) | IEC 60645-1 2012, 5/12 Octave filter with the same center frequency resolution as pure Tone Synchronous masking: Locks channel 2 attenuator to channel 1 attenuator | |
Presentation | Manual or Reverse. Single pulse. Multiple pulses 50-5000 msec. on/off | |
Intensity | AC: -10 to 120 dB HL BC: -10 to 80 dB Available Intensity Steps is 1, 2 or 5dB Extended range function: If not activated, the Air Conduction output will be limited to 20 dB below maximum output Extended range only available when mains powered | |
Frequency range | 125Hz to 8kHz. (125Hz, 250Hz, 500 Hz, 750Hz, 1500Hz or 8kHz may freely be deselected) |
SPECIFICATION | ||
---|---|---|
Model | AD629 | |
Manufacturer | Interacoustics | |
Country of Origin | Denmark | |
Included Parts |
|
|
Optional Part |
|
|
Available Tests | Basic License | Extended License |
Basic Audiometry | X | X |
ABLB | X | X |
SISI | X | X |
Speech | X | X |
Stenger | X | X |
Modified Hughson Westlake | X | X |
Weber | X | X |
Quick SIN (Optional) | X | X |
TEN Test (Optional) | X | X |
High Frequency (Optional) | X | X |
Bekesy | X | |
Langenbeck (tone in noise) | X | |
Binaural speech | X | |
Hearing loss simulator | X | |
MHA | X |
TECHNICAL SPECIFICATION | ||
---|---|---|
Power Supply | 240V / 1.5A | |
Weight | 3.3kg / 6.3lb | |
Dimensions (L×W×H) | 36.5 x 29.5 x 6.5 cm / 14.4 x 11.6 x 2.6 inches | |
Display | 5,7 inch | |
Compatible Software | Diagnostic Suit – Noah OtoAccess | |
Warm Up Time | Approximately 1 minute | |
Patient Response Switch | Two push Button | |
Operation Environment | Temperature: 15 – 35 °∁ Relative Humidity: 30 – 90 % Ambient Pressure: 98 – 108 kPa |
|
Monitor | Output through built-in speaker or through external earphone or speaker. | |
Stimuli | Tone | 125-8000Hz. Resolution 1/2-1/24 octave |
Warble Tone | 1-10 Hz sine +/- 5% modulation | |
Wave file | 44100Hz sampling, 16 bits, 2 channels | |
Masking | Automatic selection of narrow band noise (or white noise) for tone presentation and speech noise for speech presentation. | |
Presentation | Manual or Reverse. Single or multiple pulses | |
Frequency Range | 125Hz to 8kHz (Optional High Frequency: 8 kHz to 20 kHz) 125Hz, 250Hz, 750Hz, 1500Hz and 8kHz may freely be deselected | |
External Signal | Speech replaying equipment connected to the CD inputs must have a signal-to-noise ratio of 45 dB or higher. The speech material used must include a calibration signal suitable for adjusting the input to 0 dBVU. | |
Free Field output (non-powered) | Power Amplifier and Loud Speaker (With an input of 7 Vrms – Amplifier and loudspeakers must be able to create a Sound Pressure Level of 100 dB in a distance of 1 meter) | |
Internal Storage | 250 patients and unlimited sessions/measurements/audiograms | |
External Devices (USB) | Standard PC mouse and Keyboard (for data entry) Supported printers (Please contact distributor for a list of approved printers) | |
Patient Communication | Talk forward and talk back |
SPECIFICATION | ||
---|---|---|
Model | AA222 | |
Manufacturer | Interacoustics | |
Country of Origin | Denmark | |
Included Parts |
|
|
Optional Part |
|
|
Available Tests | Basic License | Extended License |
Basic Audiometry | X | X |
ABLB – Fowler | X | X |
SISI | X | X |
Speech | X | X |
Stenger | X | X |
Auto Hughson Westlake | X | X |
Speech Ch2On | X | |
Speech in Noise | X | X |
Weber | X | X |
Quick SIN | Optional | Optional |
Tymp 226Hz | X | X |
Ipsi Lateral Reflex | X | X |
Contra Lateral Reflex | X | X |
ETF 1 test non-perforated tympanic membrane | X | X |
ETF 2 test perforated tympanic membrane | X | X |
Reflex decay | X | X |
Tymp 678, 800 & 1000Hz | X | |
Manual tympanometry | X | |
ETF 3 patulous tympanic membrane | X | |
Reflex latency | X |
TECHNICAL SPECIFICATION | ||
---|---|---|
Power Supply | 240V / 1.5A | |
Weight | 3.1kg / 6.8lb | |
Dimensions (L×W×H) | 9×33×44 cm / 3.5×13×17.3 inch | |
Compatible Software | Diagnostic Suit – Noah OtoAccess | |
Warm Up Time | Approximately 1 minute | |
Patient Response Switch | Two push Button | |
Operation Environment | Temperature: 15 – 35 °∁ Relative Humidity: 30 – 90 % Ambient Pressure: 98 – 108 kPa |
|
Monitor | Output through built-in speaker or through external earphone or speaker | |
Audiometry Measure System | ||
Stimuli | Tone | 125-8000Hz. Resolution 1/2-1/24 octave. |
Warble Tone | 1-10 Hz sine +/- 5% modulation | |
Pediatric Noise | A special narrowband noise stimulus. The bandwidth is frequency depended 125-250 Hz 29%, 500Hz 24%, 750 Hz 20%, 1kHz 17%, 1.5kHz 13%, 2kHz 11%, 3kHz 9% from 4kHz and up is fix 8%, | |
Wave file | 44100Hz sampling, 16 bits, 2 channels | |
Masking | Automatic selection of narrow band noise (or white noise) for tone presentation and speech noise for speech presentation. | |
Presentation | Manual or Reverse. Single or multiple pulses. | |
Frequency Range | 125Hz to 8kHz (Optional High Frequency: 8 kHz to 20 kHz) 125Hz, 250Hz, 750Hz, 1500Hz and 8kHz may freely be deselected | |
External Signal | Speech replaying equipment connected to the CD inputs must have a signal-to-noise ratio of 45 dB or higher. The speech material used must include a calibration signal suitable for adjusting the input to 0 dBVU. | |
Free Field output (non-powered) | Power Amplifier and Loud Speaker (With an input of 7 Vrms – Amplifier and loudspeakers must be able to create a Sound Pressure Level of 100 dB in a distance of 1 meter) | |
Internal Storage | 500 patients and unlimited sessions/measurements/audiograms | |
External Devices (USB) | Standard PC mouse and Keyboard (for data entry) Supported printers (Please contact distributor for a list of approved printers) | |
Patient Communication | Talk forward and talk back | |
Impedance Measuring System | ||
Probe tone | Frequency level | 226 Hz, 678 Hz, 800 Hz, 1000 Hz; pure tones; ±1% 85 dB SPL (≈ 69 dB HL) ±1.5 dB |
Air pressure | Control: Indicator: Range: Pressure limitation: Pump speed: | Automatic. Measured value is displayed on the graphical display. -600 to +400 daPa. ±5% -750 daPa and +550 daPa. Automatic, Fast 300 daPa/s, Medium 200 daPa/s, Slow 100 daPa/s, Very slow 50 daPa/s. |
Compliance | Range | 0.1 to 8.0 ml at 226 Hz probe tone (Ear volume: 0.1 to 8.0 ml) and 0.1 to 15 mmho at 678, 800 and 1000 Hz probe tone. All ±5% |
Test Types | Tympanometry | Automatic, where the start and stop pressure can be user programmed in the setup function. Manual control of all functions |
Eustachian tube function 1 – Non perforated eardrum | Williams test | |
Eustachian tube function 2 – Perforated eardrum | Toynbee test | |
Eustachian tube function 3 – Patulous Eustachian tube | Continuous sensitive impedance measurement | |
Reflex Function | ||
Signal Sources | Tone – Contra, Reflex: THD: | 250, 500, 1000, 2000, 3000, 4000, 6000, 8000 Hz, Wide Band, High and Low pass. Less than 5 until 110 dB, 5 % above 110 dB (supra-aural headphones), less than 5 % until 110 dB, 10 % above 110 dB (insert earphones or probe). |
Tone – Ipsi, Reflex | 500, 1000, 2000, 3000, 4000 Hz wide band, high and low pass. | |
NB noise – Contra, Reflex | 250, 500, 1000, 2000, 3000, 4000, 6000, 8000 Hz | |
NB noise – Ipsi, Reflex | 1000, 2000, 3000, 4000 Hz | |
Stimulus duration | 750 ms | |
Reflex Acceptance | Adjustable between 2 % and 6 %, or 0.05 – 0.15 ml change of ear canal volume | |
Intervals | Down to 1 dB step size | |
Intensity max | 90, 100, 120 dB HL | |
Outputs | Contra Earphone | TDH39 earphone, DD45 earphone, CIR insert and/or EARtone 3A insert, IP30 for Reflex measurements |
Ipsi Earphone | Probe earphone incorporated in the probe system for Reflex measurements | |
Probe connection | Connection of the electrical and air system to the probe | |
Test types | Manual Reflex | Manual control of all functions |
Automated Reflex | Single intensities Reflex growth | |
Reflex Decay | Automatic, 10 dB above threshold and manually controlled with stimulus durations of 10 s. | |
Reflex Latency | Automated, first 300 ms from stimulus start |
SPECIFICATION | ||
---|---|---|
Model | Affinity 2.0 | |
Manufacturer | Interacoustics | |
Country of Origin | Denmark | |
Included Parts | ||
AC440 Module
|
REM 440 Module
|
HIT 440 Module
|
Optional Parts: | ||
AC440 Module
|
REM 440 Module
|
HIT 440 Module
|
Tests: (some are optional) | ||
AC440 Module
|
REM 440 Module
|
HIT 440 Module
|
TECHNICAL SPECIFICATION | |||
---|---|---|---|
Dimensions (LxWxH) | 42 x 38 x 14 cm / 16.5 x 15 x 5.5 inches | ||
Weight | 5.5 kg / 12.1 lbs | ||
Power supply | 100-240 V~, 50-60Hz | ||
Power Consumption | 195VA | ||
Operation environment | Temperature: 15-35°C Re. Humidity: 30-90% Non condensing | ||
Transport and storage | Transport temperature: -20-50°C Storage temperature: 0-50°C Re. Humidity: 10-95% Non condensing | ||
Data Connections | USB/PC | USB B socket for connection to PC (compatible with USB 1.1 and later) | |
USB | USB A socket for connection of other USB devices (Internal USB 1.1 hub) | ||
Keyb. | Serial Peripheral Interface Bus (SPI interface) | ||
Internal test box | Built in test box holds telecoil drive as well as special dual speaker set for checking directional microphone function | ||
Supported Systems | Windows® 7 (32 and 64 bit) Windows®8 (32 and 64 bit) Windows® 10 (32 and 64 bit) | ||
PC requirements | 2 GHz Intel Core 2 Duo CPU 2GB Ram 1.5 GB available disk space1024x768 resolution (1280×1024 or higher recommended) Hardware accelerated DirectX/Direct3D graphics card. One or more USB ports, version 1.1 or higher. DVD-Rom drive |
||
Display | 1024×768 resolution (1280×1024 or higher recommended) Hardware accelerated DirectX/Direct3D graphics card | ||
Disc Space | 1.5 GB available disk space | ||
Operative System | Windows® 7, Windows ® 8, Windows® 10 | ||
Compatible software | Noah 3.7, Noah 4,, OtoAccessTM and XML compatible Affinity2.0 / Equinox2.0 Suite | ||
Input Specifications | Talk Back | 330μVrms at max. input gain for 0dB VU-reading Input impedance : 47.5KΩ | |
Mic. 1/TF & Mic. 2 | |||
Pat. Resp. L & R | Switches 3.3V to the logic input. (The switch current is 33μA) | ||
Inp. Aux. 1 & 2 | 20mVrms at max. input gain for 0dB VU-reading Input impedance : 15KΩ | ||
TB Coupler | |||
TB Coupler – internal TB | |||
(Affinity2.0 .0 only) Insitu L & R – Probe mic. | |||
CD1 & CD2 | 10mVrms at max input gain for 0dB VU-reading Input impedance : 10kΩ | ||
TB Ref. | 7mVrms at max. input gain for 0dB VU-reading Input impedance : 4,3KΩ | ||
TB Ref – internal TB | |||
(Affinity2.0 .0 only) Insitu L & R – Ref. mic | |||
Ref.Mic./Ext. | Not in use | ||
Coupler/Ext. | |||
Wave files | Plays wave file from hard disk drive | ||
Output Specifications | FF1 / FF2 (Terminal Block) | Up to 12.6Vrms by 8 Ω load 70Hz-20kHz ±3dB | |
TB Lsp. | |||
FF1/ FF2 | Up to 7Vrms by 600Ω load 70Hz-20kHz ±3dB | ||
Sp 1, Sp 2, Sp 3, Sp 4 | |||
Left, Right | Up to 7.0Vrms by 10Ω load 70Hz-20kHz ±3dB | ||
Ins. Left, Ins. Right | |||
Bone | |||
Ins. Mask. | |||
HF/HLS | |||
Insitu L, Insitu R | |||
Monitor, Ass. Mon. | Max.3.5Vrms. by 8 Ω load |
SPECIFICATION | |
---|---|
Model | Eclipse |
Manufacturer | Interacoustics |
Country of Origin | Denmark |
Included Parts |
|
Optional Part |
|
Test types / Functionality |
|
TECHNICAL SPECIFICATION | ||
---|---|---|
Power Supply | Input Volt: 100-240VAC / 50/60Hz Consumption: 26W (0.3A max) | |
Weight | 2.5kg / 5.5lb including accessories | |
Dimensions (L×W×H) | 28×32×5.5 cm / 11×12.6×2.2 inch | |
Construction | Metal cabinet | |
Compatible Software | Diagnostic Suit – Noah OtoAccess | |
Display | XML Compatible | |
Warm Up Time | 10 minutes at room temperature | |
PC Control | USB 1.1 or 2.0 for input/output for computer communication Eclipse is fully operated from a PC | |
Operation Environment | Temperature: 15 – 35 °∁ Relative Humidity: 30 – 90 % Ambient Pressure: 98 – 104 kPa |
|
EP 25 / VEMP Specifications | ||
EPA Preamplifier | Two channels standard | EPA4 Cable Collector (4 electrodes). Standard 50 cm. Option: 5cm or 290 cm |
One Channel (optional) | EPA3 Cable Collector (3 electrodes). 50 cm | |
Gain: | 80 dB/60 dB | |
Frequency response: | 0,5 – 5000 Hz | |
CMR Ratio: | Minimum >118 dB. Typical 130 dB < 100 Hz | |
Radio frequency | Typically 25 dB improvement over previous available | |
Max input offset | desig | |
Input impedance | 10 MΩ/ 170 pF | |
Power from main unit | Insulated power supply with 1500 V isolation. The signal is digitally/capacitive insulated | |
Stimulus: | Stimulus rate: | 0.1 to 80.1 stimuli per second in steps of 0.1. |
Envelopes/Windows : | Bartlett, Blackman, Gaussian, Hamming, Hanning, Rectangle and Manual (Rise/Fall and Plateau) | |
Masking: | White noise. Calibrated and presented in SPL. | |
Transducer: | Ear Tone ABR insert phone, calibrated on an IEC 711 coupler.Headphone with independent calibration (optional) Bone conductor (optional) | |
Level | 20 – 135.5 dB peSPL, (-10 – 100 dB nHL) in 1 dB steps | |
Polarity: | Condensation, Rarefaction, Alternating | |
Click: | 100 μs (200Hz -11kHz) | |
Tone Burst Frequency | 250, 500, 750, 1000, 1500, 2000, 3000, and 4000 Hz. | |
Tone Burst Stimulation Time: | Stimulation up to 780 ms | |
NB CE-Chirp® LS Freq.: | 500, 1000, 2000 and 4000 Hz | |
Broadband CE-Chirp®: | 200Hz -11kHz | |
LS 200Hz -11kHz Relative Masking Level: | +30dB to -40 dB relative to stimulus level. The stimulus level ispresented in nHL. The masking level is only presented in SPL, and can therefore not exceed the loudness of the stimulus. | |
Recording: | Analysis Time: | -150 ms prior to stimuli and up to 1050 ms dependent). |
A/D Resolution | 16 bit. | |
Sampling frequency | 30 kHz | |
Artifact Reject System: | Standard voltage based system | |
Rejection levels: | Manual 0.2 – 640 μV input with 0.1uV steps. | |
Anti-aliasing filter | Analog 5kHz, 24 dB / octave | |
Dots per Trace: | 450 displayed. | |
Low Pass Filter: | None or 17 – 12000 Hz depend on the measurement type | |
High Pass Filter: | 0.83 Hz to 500 Hz depending on the measurement type. | |
DSP Low Pass Filter: | 100, 300, 750, 1k, 1,5k, 2k, 3k, 4k, 5k, 7,5k Hz | |
DSP High Pass FilterDSP High Pass Filter | 0.5, 1.0, 3.3, 10, 33, 100 Hz | |
Display Gain: | General Display Gain. Applicable during testing. Single Curve Display Gain. Applicable during testing. | |
Controlled parameters: | Stimuli Rate, Number of stimuli, Polarity, Click, Tone Burst, Stimulus intensity, Number of curves per intensity, Intensity, Soft attenuator, Stimulus ear, Transducer, Masking level, Preliminary filter setting, Recording onset, Automatic next intensity, General Display Gain, Single Curve Display Gain, Baseline, Latency norm, Report templates, Print out, Manual stimulus to familiarization, Talk Forward. | |
Data collection: | Impedance test, Waveform buffer, Curve, Online EEG, Waveforms storage in unlimited storage database | |
Data Recovery: | Lost data due to crash of Windows® will in almost all cases be Available upon re-establishing Windows operation. | |
TEOAE 25 Specification | ||
Stimulus: | Type: | Click (Linear or Non-linear) |
Bandwidth: | 500 – 5500 Hz | |
Level: | 50-90 dB SPL | |
Level Step: | 1 dB SPL | |
Transducer: | Dedicated TEOAE25 probe (Accuracy 0.5 dB) | |
Recording: | Recording: Analysis time: | 25 to 32000 samples |
Sampling frequency | 30 kHz | |
A/D Resolution | 16 bit, 3.7 Hz resolution | |
Artifact Reject System: | 25 – 55 dB SPL or off. Applicable during testing | |
SNR Criteria | 5 individual frequency bands can be set 1-30 dB SPL | |
Display gain: | General Display gain | Applicable during testing |
DPOAE 20 Specification | ||
Stimulus: | Frequency Range: | 500-8000 Hz |
Frequency Step: | 50 Hz | |
Level: | 30-75 dB SPL (70 dB above 6kHz) | |
Level Step | 1 dB SPL | |
Transducer: | Dedicated DPOAE20/TEOAE25 probe | |
Recording: | Analysis time: | minimum 2 sec to unlimited test time |
A/D Resolution | 16 bit, 3.7 Hz resolution | |
Sampling frequency | Sampling frequency | |
Artifact Reject | -30 – 30 dB SPL or off. Applicable during testing | |
Stimulus Tolerance | Adjustable | |
SNR Criteria | Adjustable | |
Probe check window | 256 points frequency response of the ear canal due to a click | |
DP-Response window | 4096 point frequency response | |
Display gain: | General Display gain | Applicable during testing |
EPA Preamplifier | Two channels standard | EPA4 Cable Collector (4 electrodes). |
One Channel (optional): | EPA3 Cable Collector (3 electrodes). 50 cm | |
Gain: | 80 dB/60 dB | |
Frequency response: | 0,5 – 5000 Hz | |
CMR Ratio: | Minimum >118 dB. Typical 130 dB < 100 Hz | |
Radio frequency immunity: | Typically 25 dB improvement over previous available designs | |
Max input offset voltage | 2,5 V | |
Input impedance: | 10 MΩ/ 170 pF | |
Power from main unit: | Insulated power supply with 1500 V isolation. The signal is | |
Specifications as EPA4 Impedance measurement: | Selectable for each electrode | |
Measurement frequency | 33 Hz | |
Waveform | Rectangular | |
Measurement current | 19μA | |
Range: | 0.5 kΩ – 25 kΩ | |
Stimulus: | Stimulus rate: | 93 Hz |
Level: | 30, 35, 40 dBnHL | |
Click: | 100 μs | |
Recording: | Analysis time: | 120 seconds |
A/D resolution: | 16 bit | |
Sampling frequency | 30 kHz | |
Artifact rejection system | Standard voltage based system | |
Display: | Stimulus level and type, Graph view | |
Security: | Password protection of test parameters possible. | |
Algorithmic | Click: | 99.99% |
Sensitivity | Click: | ≥ 97% |
ABRIS Module Specification | |
Stimulus type | Click |
Stimulus rate | 93 Hz |
Stimulus intensity | 30, 35, 40dB nHL |
Test time | 120 seconds (default) |
Test montage | mastoid or nape |
Test method | monaural |
User customizable protocols | X |
Password protection of test parameters | X |
ASSR Module Specification | |
Stimulus level | 0 – 100 dB nHL |
Narrow Band CE-Chirp® stimuli (0.5, 1, 2, 4 kHz) | X |
Recording time | Up to 15 min per curve |
Stimulus rate | 40 or 90 Hz |
Transducer options | Headphone, DT48A, Inserts, Bone |
nHL to eHL correction factors (Child/Adult) | X |
Residual noise calculator | X |
User customizable protocols | X |
Noah 4 and higher compatibility | X |